MF420-Ex-2.1
The probe MF420-Ex 2.1 is approved for operation in hazardous areas of zone 1 and zone 2 and has an EU-type examination certificate in accordance to Directive 2014/34/EU (ATEX) with the following certificate and labeling:
IBExU 12 ATEX 1080 X
Ex II 2G Ex db eb IIC T6/T4 Gb
Ambient temperature range:
T4: -40°C to +60°C / T6: -40°C to +50°C
The modular design of the sensor allows to equip it with a catalytic sensor (Pellistor) for determining the concentration of explosive gases and vapors, or with an electrochemical sensor for toxic gases depending on the variant. The concentration is output from the 4 - 20 mA interface, for further processing.
The measuring ranges depend on the measured gas or vapor. For a table of ranges please refer to the product assortment. Other gases, vapors, and concentrations are also possible on request. The device has been approved in accordance with the directive 2014/34/EU (ATEX) with the type examination certificate IBExU 12 ATEX 1080 X. It was tested according to the standards EN 61000-6-2 and EN 61000-6-3 and EN 50270 and complies with the EMC Directive 2014/30/EU. The device is delivered already calibrated. The maintenance cycle must / should correspond to the given safety requirements. We recommend at least a semi-annual inspection of the equipment by qualified personnel. You can also use our service. For more details, please refer to the technical data or ask our contact person.
Other gases and vapors on request.
Measuring ranges
Certifications
Maintenance and service
Product Name Product Features Product Code
MF420-Ex-2.1
Hydrogen, LEL 4 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O17
MF420-Ex-2.1
Methane, LEL 4.4 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O11
MF420-Ex-2.1
Propane, LEL 1.7 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O12
MF420-Ex-2.1
n-Butane, LEL 1,4 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O03
MF420-Ex-2.1
LPG (50%-50%), LEL 1.5 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O50
MF420-Ex-2.1
Ethanol, LEL 3.1 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O05
MF420-Ex-2.1
Methanol, LEL 6 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O20
MF420-Ex-2.1
i-Propanol, LEL 2 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O08
MF420-Ex-2.1
Xylol, LEL 1 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O18
MF420-Ex-2.1
n-Heptane, LEL 0.8 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O07
MF420-Ex-2.1
Acetylene, LEL 2.3 vol%
Measuring range 0 - 100% LELG2E0-P19JU-A100-O01
MF420-Ex-2.1
Carbon monoxide
Measuring range 0 - 300 ppmG2E0-E10LP-A100
MF420-Ex-2.1
Oxygen
Measuring range 0 - 25 vol%G2E0-E13WV-A100
Principle of Measurement
catalytic (pellistor) or electro chemical sensor
Power Supply
Voltage
18 V to 30 V DC
Current
approx. 105 mA at 24 V
Ambient Temperature
-40°C to +60°C
-40°C to +50°Cfor temperature class T4
for temperature class T6Air pressure
700 hPa to 1300 hPa
Permissible Humidity
10 to 95% relative humidity
non condensing
Output
4 - 20 mA
max. Load 500 Ω (Error status at I
Housing
Alloy composition / Stainless steel
Protection class
IP 65
Weight
ca. 1100 g
Dimensions (D x H)
ca. ∅84 x H78 mm
Connecting Cable
3-wire shielded cable
Recommended cable cross-section minimum 1.5 mm2
Certifiction
EC-type examination certificate in accordance with the directive 94/9/EC (ATEX)
IBExU 12 ATEX 1080 X
Ex II 2G Ex db eb IIC T6/T4 GbPin Assignment:
Product Name Product Features Product Code
Replacement Sensor Set
Consists of:
- Replacement sensor
- Sealon request
Calibration Set
Consists of:
- Test gas cap
- O-Ringon request